Spandrel:
0.750 to 0.900W/m²·K/0.132 to 0.159Btu/ft²·°F·hr
#object[Error Error: No matching clause: ]
#object[Error Error: No matching clause: ]
#object[Error Error: No matching clause: ]
Transmittance ranges: | |
---|---|
Clear Wall | 0.096 to 0.149W/m²·K/0.017 to 0.026Btu/ft²·°F·hr |
Construction types | Wood-Framed and Timber |
The following parameters are constant across the scenarios for this detail:
406 mm | horizontal spacing of framing and secondary attachments |
---|---|
406 mm | vertical spacing of secondary elements |
None | exterior insulation |
sub-reference | interior/cavity insulation | clear field effective R-value | clear field transmittance | |
---|---|---|---|---|
A | RSI 6.78 | RSI 6.70 | 0.149 W/m²·K | |
B | RSI 7.75 | RSI 7.47 | 0.134 W/m²·K | |
C | RSI 9.69 | RSI 8.94 | 0.112 W/m²·K | |
D | RSI 11.62 | RSI 10.37 | 0.096 W/m²·K |